What Is an EICR? A Peterborough Landlord and Homeowner Guide (2026)

By 360 Maintenance Solutions Ltd·Published ·Updated

What Is an EICR?

An Electrical Installation Condition Report (EICR) is a formal assessment of the fixed electrical installation inside a property — the wiring, consumer unit (fuse box), sockets, switches, earthing and bonding. A qualified electrician tests every circuit and grades any issues found using a standardised code system.

Is an EICR a Legal Requirement for Landlords in Peterborough?

Yes. The Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020 made EICRs a legal requirement for all private landlords in England. Every rental property must have a valid EICR in place and landlords must provide a copy to tenants.

EICR requirements for Peterborough landlords:

  • Electrical installations must be inspected at least every 5 years, or sooner if the report specifies
  • A copy must be provided to the incoming tenant before or at the start of their tenancy
  • Existing tenants must receive a copy within 28 days of the inspection
  • If unsatisfactory, remedial work must be completed within 28 days (or less if specified)
  • The local authority (Peterborough City Council) can demand a copy at any time

What Do the EICR Fault Codes Mean?

CodeMeaningAction Required
C1Danger present — risk of injuryImmediate action required
C2Potentially dangerousUrgent remedial work needed
C3Improvement recommendedNo legal obligation, but advisable
FIFurther investigation requiredCannot grade without more testing

Only C1, C2 and FI observations result in an unsatisfactory report. A C3-only report is satisfactory.

What Does an EICR Inspection Cover?

During an EICR in Peterborough, our qualified electricians inspect and test:

  1. The consumer unit (fuse box) — condition, type and compliance
  2. All circuits — continuity, insulation resistance and polarity
  3. RCDs (residual current devices) — correct operation and trip times
  4. Earthing and bonding arrangements throughout the property
  5. Sockets, switches and accessories — condition and correct wiring
  6. Fixed electrical equipment such as immersion heaters and storage heaters

What Happens After an Unsatisfactory EICR?

If your Peterborough rental property receives a C1 or C2 observation, you are legally required to complete the remedial work within 28 days (or the timeframe stated on the report, if shorter). 360 Maintenance Solutions can carry out all follow-up electrical remedial work and re-inspect to issue a satisfactory certificate.

Book an EICR in Peterborough

Call 07766 184141, WhatsApp us on 07383 512577 (quickest response), or submit a quote online. Every property is priced individually — no hidden fees.

👉 View our EICR service page

Ready to get a quote?

Call, WhatsApp or submit a quote request — we reply quickest on WhatsApp.